Others
ITS-100
Tester

 ■ Termination Mode (B-Linx Termination Mode, ECP/EUP/ETP products)

 

  • Provides information about the cables used where the camera will be installed.
  • Shows the power consumption (Watt) available for the measured cable (Review of the PoE cameras that can be installed is possible).
  • Cable resistance (Ohm) from the receiver (Rx) to the tester.
  • Voltage supplied from the receiver (Rx) to the tester (The tester measures overvoltage and undervoltage, not the supply voltage).
  • Shows an Error when an operation failure is likely to happen on a PoE product (based on the cable voltage drop).
  • Shows the measurement information (periodic measure, shown on the Display window).
  • The tester does not work if it is not connected to a receiver (Rx). The tester does not have a battery, and operates with the output voltage of the receiver (Rx).

 

■ Bypass Mode (cable connection mode, PoE)

 

  • The tester is set in the middle of the PoE cable and measures the cable performance while the camera is in operation.
  • Measures the power consumption (Watt) while the camera is in operation.
  • Measures the cable voltage (Volt) while the camera is in operation.
  • Measures the power consumption of the camera when the tester is installed on the camera side.
  • Shows real-time measurements (periodic measure, shown on the Display window).
  • Operates when a PoE camera (PD device) is connected to the PoE Output terminal.
  • The tester might not work if it is not used with a PD device. (The tester does not have a battery, and operates with the output voltage from the PSE).​

 